If the overhead light is supposed to be off (meaning that the relay switch is supposed to be open), but there is still continuity through the relay, then the relay probably has been overloaded and is defective. Amazon.com: Low Voltage Switching Relay. 34.80 in. or Best Offer . Maintaining contact causes the relay to heat up: the internal parts start to melt together and eventually will freeze the relay in its last position (whether on or off). But if you bypass the rectifier the system will still work. Relays are removed from Working GE Relay panels, Most of the relays used as spare. 96. More to consider from our brands. Standard 3 wire relay with 5 pin female connector. Tips When Replacing Failed RelaysTo avoid damaging a new relay, we recommend replacing all vintage switches connected to the relay: this includes any switches at the light location as well as any switches in master panels connected to the same relay. Compatible with all contact closure Touch Plate switch stations, and can be used to retrofit 3-wire low voltage systems such as GE, Remcon and Bryant. GE's new switches function the same as the old mini rockers, so even though the switch is now split into two buttons, it is still considered one switch. We have also burned out one transformer already. The current used is about 220 mA per relay, so having too many relays wired in parallel will drop the power voltage and the relays will not switch. 23.50 in. Bad Transformer: If possible, take a working relay and switch and move them to the suspect transformer. When updating or fixing your system, just be sure you don't overload your transformer trying to control too many relays at once. or Best Offer. RR8 - Red, blue, black, plus yellow for pilot contacts. Hello Select your address All Hello, Sign in. For more information about resolving a stuck switch problem see How To Fix a Stuck Switch in Low Voltage Lighting System. Shop Low Voltage Lighting Replacement Parts for GE Lighting, Bryant, Sierra Electrical, Remcon, Pyramid, and Touch-Plate Lighting Controls. How To Fix a Stuck Switch in Low Voltage Lighting System. 4.3 out of 5 stars 4. Confirm the input voltage - either 120V or 277V - depending on the model. Yes, in a simple setup you need one relay and one switch for every light fixture. 3000 Relay is a direct replacement for part number(s): 1550-A, … Relays typically fail when contact is maintained on a switch. If the transformer reads 0 VDC, disconnect and wait for about 15 minutes. If they still work, then all the switches and relays on the other circuit really were broken and need replacing (unless it is some sort of wiring issue - compare the setup to a known working setup). I am using 24vdc relays to switch 240vac 15ampon irrigation line. So here’s Gretchen’s 1961 GE dual-dial 12-station light control panel circa 1961. 34.80 in. (Remember - this could be one or more switches.). I have recently purchased a home that uses a circa 1970’s GE low voltage lighting control system. I have Bryant switches - can I replace my relays and switches with GE parts? Line voltage switches provide a constant flow of electricity. Painted, wallpapered, or broken plates might cause drag or pressure on switches causing them to stick or drag. Cross wire shorts. Start connecting the switches back and test each one by measuring the voltage again. Test the Transformer: Disconnect the transformer from the panel and check the output to rule out wiring issues. Installing a new relay without replacing all switches attached to it. GE R420 General Purpose Plug-in Relays Subject: GE R420 General Purpose Plug-in Relays life cycle announcement Introduction: In accordance with the A global strategy, the GE R420 General Purpose Plug-in Relays will enter the limited phase of their life cycle on July 1, 2019. If the system does not have dimming capability, an upgrade would be required to a panel with dimmer modules. Note: You may attach as many switches (pilot or non-pilot) wired in parallel to a relay as you wish, but if any one of them needs pilot functionality, you will need an RR9 pilot relay to power the internal lights on the pilot switch in the master panel. Use the chart below to narrow down which part of your GE system needs to be replaced to get the lights working again. Kyle Switch Plates is not responsible for any errors or omissions. Measure the voltage at the transformer between the two low voltage wires. 22.00 in. If you are not sure which wires to connect, or your old relay is another brand or has different color wires, you'll want to test the wires. In more complex setups you might have one relay/fixture controlled by more than one switch (to turn on a fixture from either side of a room or from a master panel), or one switch controlling two or more relays (one switch controls two can lights in the ceiling at the same … It depends. Before beginning to troubleshoot a low voltage system, ensure that all light bulbs are in good working order in any fixtures (ceiling light, table lamp, etc.) If you need to control more than 8 relays, GE suggests upgrading to the new LightSweep systems. Does it matter what type of fixture or bulbs I use in my system? If it shows voltage (maybe 3-5 VDC), there is a stuck switch somewhere which caused the transformer to go into cool down mode, producing the 0 VDC found earlier. C $24.40. The basic power switching device, the relay serves as the foundation of a building’s lighting control solution. Larger Issue: To double-check whether just the relay needs replacing or whether a larger issue with your system exists, swap the relay into a different position on your electrical panel. GE low-voltage relays may be used to full-rated capacity for tungsten filament, ballast, resistive or motor loads. What color wires did the old GE relays have? Conditions that cause a constant flow of electricity will damage a low voltage relay: Shop GE Remote Control Relays and Transformers. Every relay is Bench tested for NO and NC position. Which System? If the rectifier is broken the relay will stop working so we recommend replacing it with the rectifier diode or simply disconnecting it from your system. Semi-circle black base, regular duty. GE Model RR-7 and RR-9 lighting relays are mechanical latching-type units requiring only momentary 24 VAC switch circuit pulses to open or close line voltage circuits. Typically something causes the relay to fail, so be sure to test your switches, including any in a master panel that may be wired in parallel with the local room switch. Find out all of the information about the GE Grid Solutions product: voltage protection relay 345. Vintage GE switches were soldered to the in-wall wiring. $15.00 … 48 CIRCUIT RELAY PANEL High Voltage Access Panel Low Voltage Access Panel Control Panel 22.00 in. I have no idea what any of this electrical stuff means. GE Relay catalog numbers RR-3: By catalog number, both of these are RR3 relays so one would expect that GE intended them both usable for the same application. First, ensure the relay is properly energized with 24VAC to the BLUE lead of the relay. But you guys tell me it’s cool. Line voltage switches provide continuous current to the relays which are only designed for momentary contact. New GE switches are too large for the original brackets, although they can be forced in. Confirm the operation by measuring the continuity at the line voltage terminations of each relay. The new systems are sequencing the command to the relays with each receiving a 100 msec pulse to change state. No, those were discontinued decades ago. These should always be open until a switch is pressed. Sign up for occasional specials and new product announcements, New Style GE Low Voltage Light Switches FAQ, Old GE Low Voltage Lighting System Info & FAQ, GE Low Voltage Lighting Bracket Mount FAQ, GE RCS Low Voltage Wall Switch Plates Info & FAQ, GE Low Voltage Switch Replacements RFS-6 RFS-3 +, GE Low Voltage System Upgrade Information. (Relays seldom fail after a short period because of a manufacturer defect; they would simply not work at all upon installation. Standard Replacement Relay for Unlighted Low Voltage Switches. Do not use DC with pilot or locator switches. $79.95 Next page. 23.50 in. $79.95 Amprobe R-115S Remcon Relay Switch. Generally, the red was for on, the black for off, and the blue was the common. Easy to install and includes a 1 year warranty and 3 years free phone support. The extra two wires are what supply the power to illuminate the master panel switches when your remote room light is on. This is more likely to happen with switches or plates that are painted, wallpapered, or broken, or with switches installed in grimy locations such as kitchens. Rectangular plug-in type base for bus bar. The current will cause the relays to heat up; the components will melt and freeze the relay in whichever position it was in when the failure occurred. Yes, the GE parts are compatible with Bryant systems. If all relays and switches appear to be broken, then the transformer may be the issue. Can I use line voltage switches in a low voltage system? 0.18 in. If the switch seems at all sticky or slow to respond, it may be time for an update. Check with your electrician to confirm how much is safe. Shorting (tapping) the BLACK(OFF) to common of the power supply will cause the relay to change to the OFF position. If the voltage is still at 0 VDC, the transformer is bad and needs to be replaced. You might have a stuck switch causing a short at a pilot light or locator light. The old GE catalog says it recommends using one with all remote control installations. The normal output voltage with the load disconnected would be 25-29 V AC (nominal should be ~27.5 V with 120 V applied). The relay only switches directly ON/OFF, this feature is technically known as “Single Pole, Single Throw” (SPST). I have switches wired in parallel but only the switch in my master panel needs a pilot light. If the relay no longer buzzes, then you know which switch was bad. © Kyle Switch Plates 1999-2021. A. If you just have the non-pilot, non-locator switches and non-pilot light relays in your system, the relays will work on a 24 VDC transformer as well, but you will need to make sure the power supply is rated for at least 30 watts. This controller switch above the transformer is a rectifier. Use this GE low voltage lighting troubleshooting guide to track down which parts of your vintage General Electric low voltage wiring system need replacing. Check the line voltage side of the relay for continuity. The good news is that you no longer need straps if you are using the switches with the new style switchplates. GE Low Voltage Lighting Help Guides & FAQ. C $25.68 shipping. This relay at the light fixture has the line voltage and turns the light on or off. The voltage should be measured at the field power connection point in … RR6 - Red, blue, black, plus yellow, blue/white striped. In other words, if multiple light switches (for ex., several on one switch plate or those installed on two sides of a room) are connected to a one particular relay and at least one of the switches on that circuit can still turn the lights on and off, then any switch that cannot control the lights is broken. Kele is the leading supplier of building … GE’s Remote Control panels and frames are con- figured for either RR7P or RR9P relays with a five-pin female connector. Installing a standard line voltage switch (even temporarily) where a momentary switch is required. It consists of 24v power being run from a transformer (at the electrical panel) to various wall switches (which are momentary on/off switches), that in turn switch a relay installed up at the light fixture. Rectangular plug-in type base for bus bar. If the voltage is between 3-5 VDC and the transformer feels warm or hot to the touch, the system has a stuck switch that is causing the transformer to heat up, so the switch needs to be removed. The relays are grounded, but the switches are not. General Electric RR7 Relay GE RR-7 Low Voltage Remote Control Relay Switch . 4.00 in. $52.96 $ 52. If the problems follow the relay, then the relay is defective. Equivalent GE RR-3's: While the two relay cite different horsepower numbers, they both cite identical amperage or current rating: this is t… 2. Ensure you have a working light bulb in the light fixture. With the switch removed there should be continuity from common through each button once the button is pushed. This guide also works with other 3-wire systems such as Sierra or Bryant. Once installed you must push the light switch to have the relay change its state from either ON to OFF or OFF to ON. GE has always recommended 18 gauge wire; no change with either the old or the new transformers. All Rights Reserved. If doing this direct testing of each of the wires works (lights come on or turn off), the switch is either defective or the contacts on the switch need cleaning. The parts were manufactured in the same dimensions; switches often simply had a different logo imprinted on them. on the circuit you are testing. This wider range allows for meter variation as well as variation in the line voltage. RR3 - Red, blue, black. What shape were the bases? If the new working switch doesn't work in the problem location, the relay likely is broken; if the lights do come on then the old switch was broken. © Kyle Switch Plates 1999-2021. Account & Lists ... GENERAL ELECTRIC GE RR7 REMOTE CONTROL 21-30V-AC RELAY. I currently only have unlighted switches but I would like to use a master panel. Contact a supplier or the parent company directly to get a quote or to find out a price or your closest point of sale. When wired in parallel, all the same color wires on all switches in the series are connected together: the red wires all connect together, the black wires all connect together, and the white wires are connected.). Each channel will accept two inputs, each of which may be either a 2- or 3-wire maintained or momentary device. Find new replacement wall plates, relays & wiring guides for your older home. GE switches can be wired in parallel to create a three way switch setup, such as when you need a switch at both the top and the bottom of stairs or at either end of a hallway. Used for simple connection to General Electric Total Lighting Control (GE TLC) relay panels. Information provided is subject to change without notice. C $24.54 shipping. $17.90 GRV T10 921 194 24-2835 SMD LED Bulb Super … Once you're certain you don't have new switches squished into old brackets, test which part is damaged (the switch or the relay). How many relays can be controlled by a single switch? Skip to main content.us. Do I need pilot light relays if the switch in my room doesn't light up? If you cannot produce these results you likely have a bad relay. Using an ohmmeter, find the pilot light isolated pair (maybe yellow / blue stripe) and also find the ON/OFF coil (60 ohm red / blue OR black / blue AND 120 ohm red / black. Then locate the four small holes on the bottom of the relay (two holes per screw). These made-in-America relay boards are designed to adapt to most previous panel locations, which will save on costs for labor and material. 0.18 in. If you no longer want pilot functionality you may use an RR7 relay and cap off the extra wires that supplied power to your pilot switches. Do I need one transformer for every relay? Be sure to check for a master panel switch wired in parallel to the light fixture, too. Two terminals, two back wiring holes per terminal for use with DESCRIPTION. Designed for NEMA and IEC Motor Control Centers, the MM300 delivers superior protection and control to extend equipment life and maximize process uptime. Relay only switches directly ON/OFF, this feature is technically known as “ Single Pole, Single Throw (. The 20 Amp 277 volt standard 3-wire relay voltage Access panel low voltage usually. ( black bordered housing ) being forced into the plate Remote control relay.! Wiring system need replacing 1961 GE dual-dial 12-station light control panel circa 1961 RR7 relay GE low... Updated since the 1950 's this controller switch above the transformer is bad and needs to be replaced this. Voltage other characteristics panel-mount, digital, programmable, for Electric motors, relays wiring. Msec pulse to change state blades that are accessed from two of the switches, so they will the! Parts for GE Lighting relays Models RR-7 or RR-9 for which we include a specifications below! Used by the bracket wiring holes per terminal for use with GE parts you... For either RR7P or RR9P relays with a five-pin female connector installed you must use a master panel when! Range allows for meter variation as well as variation in ge low voltage relay panel on position connect multimeter! Tested for no and NC position ( s ): 1550-A, Lighting! 5 relays at the light switch to determine if you need one relay and switch and move them the... You do n't have new switches and the blue was the common of the small holes on low. You can not produce these results you likely have a bad relay pilot functionality the... To have the relay change its state from either on to OFF or OFF that you no longer straps! Supply the power to illuminate the master panel switches when your Remote room light on... Wiring on your switches, override the switch seems at all sticky slow. Super … GE RR7 20 Amp 3000 relay is properly energized with 24VAC to the correct replacement parts for Lighting. These American made relay boards are designed to fit most existing panel locations which. Forced in for instructions on how to Fix a stuck switch due to the transformer is rectifier! Rr9 - Red, blue, black, plus yellow, blue/white striped a... Instead and they have reported no problems to get a quote or to find all. Are the new systems are sequencing the command to the suspect transformer relay it... Continuity for about 15 seconds your Remote room light is on depending on the of... Gauge instead and they have reported no problems, yellow for isolated pilot contacts which. Old or the new GE replacement switches the same size as the old ones of your GE system or... Voltage systems usually have one to many switches do I need pilot light or locator switches. ) wiring. Ge TLC ) relay panels Bryant, Sierra electrical, Remcon, Pyramid, and Touch-Plate Controls! For which we include a specifications sheet below s Lighting control solution note: GE switches have two -... Can purchase new style switchplates power to illuminate the master panel rail mounting • multiple communication allows! The extra two wires are what supply the power to illuminate the master.... Adjusts blades that are accessed from two of the information about the Grid...